X-RAY-250
X-Ray Flaw Detector

X-RAY-250

Product Specifications

● It adopts radiography theory to make the image on the film, in order to evaluate the work piece. ● Suitable for all power generators power supply. ● Mini size x ray generator part ,easy moving and less shock . ● Update iron core design and lower mA setting to generate less heat ● High pure degree radiator improve 30% heat radiation and high power cooling fan adopted to reach faster heat dissipation. ● SF6 gas insulator, grounded-anode design and exposure time delay function to keep the operator safety. ● Automatic warm up system , 1:1 work and rest radio, pressure indication to make easy operating for the operator.

Technical Specifications

Technical Specifications
model X-RAY-250
tube_type Ceramic Tube Directional
tube_voltage 80-250 kv
tube_current 3 mA
focal_size 2.0*2.0 mm
x_ray_exposure_angle 40°
x_ray_generator
dimension Φ218*595 mm
weight 18 kg
diameter 176 mm
max_penetration_a3_steel 39 mm
power_supply AC 190V-260V 50HZ, power > 2.5 KW
Technical Details
model ZT-4000
dimension 310*310*145 mm
weight 9 KG
max_exposure_time 5 min
work_ratio Work time: rest time = 1:1
cooling_system Air Fan
operating_temperature -25℃-40℃
focus_to_film 600 mm
exposure_time 5 min
film KODAK, double lead foil intensified
darkroom_treatment
temperature 20 ±2ºC
time 5 min
D ≥ 1.5
safe_working_pressure_of_gas 0.35 ~ 0.50 Mpa
pressure_note Operation prohibited in case less than 0.35 Mpa
Specification Images
Product Specification Image